Dormant backlight brightness | 0000 | Used to set the brightness of the backlight when the controller is un-operated for a long time. |
Gas loading pressure(Mpa) |
00.80 |
1. The pressure is higher than this value, and is in the loading operation state, controls the air compressor to unload the movement. 2. The setting value of gas supply loading pressure can not be greater than this value, and the "gas supply and unloading pressure" is limited by the "high unloading pressure limit" in the manufacturer's parameters. |
Fan motor start temperature(ºC) | 0080 | When the exhaust temperature is higher than the set value of the air compressor, control the fan operation. |
Fan motor stop temperature(ºC) | 0070 | When the exhaust temperature of the air compressor is lower than the value set here, stop the fan from running. |
Motor Starting delay time(s) | 0008 |
Set the starting time of the motor, start the time when the motor starts, in this time, the motor current overload is not protected. |
Fan motor Starting delay time(s) | 0003 |
Set the starting time of the fan motor, start the time when the fan motor starts, in this time, the fan motor ![]() ![]() ![]() ![]() ![]() ![]() ![]() current overload is not protected. |
Star angle delay time(s) | 0006 | motor star angle step-down start delay time. |
Load delay time(s) | 0002 | After the motor angle runs, the delay loading time. |
Empty load delay time(s) | 0600 |
Air compressor allows the longest continuous no-load operation time, after this time automatically stop running, into the empty car too long stop state. |
Shut down delay time(s) | 0010 |
When normal shutdown, the air compressor immediately no load operation, no load operation this setting time after the stop operation. |
Restart delay time (s) |
0100 |
After the normal stop, the empty car stops for too long or the malfunction stops, the air compressor can be restarted only after the time is set up here. |
Drainage opening delay time( s ): | 0002 | When automatic drainage control, continuous drainage time (spare). |
Drainage off delay time(min): |
0060 | When automatic drainage control, drainage interval (spare). |
Soft start delay time (s ): |
0006 |
After this delay time, enter the loading delay time. (This parameter only works if the model is set to soft start). |
Load mode: |
Manual/Auto matic |
Mode : the pressure is higher than the "unloading pressure" automatically unload ; the rest of the cases, by the loading and unloading key control. Mode : the controller automatically controls the loading and unloading of the air compressor according to the pressure and the set loading and unloading pressure. |
Menu |
Setting initial value |
Function description |
Gas loading pressure(MPa) |
00.65 |
1.The loading mode is set to be automatic,when the air compressor is in the state of automatic unloading,the pressure is lower than this value to control the automatic loading and running of the air compressor 2.When the air compressor stops for a long time,the pressure is lower than this value and the operating conditions are available.The controller automatically starts the operation of the air compressor. |
Menu | Initial value | Function description |
Oil filter using time | 0020H | Oil filter total using time. |
Oil separator using time | 0020H | Oil separator total using time. |
Air filter using time | 0020H | Air filter total using time. |
Lubricating oil using time | 0020H | Lubricating oil total using time. |
Grease using time | 0020H | Grease total using time. |
Factory code | 00000000 | Display factory code. |
Power voltage | 0000V | Display power voltage. |
Motor electricity |
A:000.0A B:000.0A C:000.0A |
Display motor electricity. |
Fan motor electricity | A:000.0A B:000.0A C:000.0A |
Display fan motor electricity. |
Motor RPM | 0000 RPM | According to the read frequency of the motor, the calculated real time speed of the motor is displayed. |
Motor output frequency | 000.0 Hz | Display current motor Frequency converter output frequency. |
Motor output electricity | 000.0 A | Display current motor Frequency converter output electricity. |
Motor output voltage | 000.0 V | Display current motor Frequency converter output voltage. |
Motor output Power | 000.0 Kw | Display current motor Frequency converter real-time output Power. |
Motor Electricity consumption |
0000000.0K w.H | Display controller according to the motor Frequency converter output real-time Power,Electricity consumption. |
Motor Total Electricity consumption |
0000000.0K w.H |
Display controller according to the motor Frequency converter output real-time Power,total Electricity consumption. |
Pressure | 00.00MPa | |
Integral coefficient | 00.00 | |
Motor state |
0000 |
The controller displays the running state register values read from the host Frequency converter to the motor status display area. |
Malfunction |
0000 |
The controller displays the value of the malfunction state register read from the host frequency converter to the malfunction display area. |
Write frequency | 000.0 | Controller displays the motor frequency value obtained out calculate by PID operation here. |
Fan motor RPM | 0000 RPM | According to the reading from Fan motor frequency,Display calculate Fan motor real-time RPM. |
Fan motor output frequency |
000.0 Hz |
Display current Fan motor Frequency converter output frequency. |
Fan motor output electricity |
000.0 A |
Display current Fan motor Frequency converter output electricity. |
Fan motor output voltage |
000.0 V | Display current Fan motor Frequency converter output voltage. |
Fan motor output Power | 000.0 Kw | Display current Fan motor Frequency converter real-time output Power. |
Fan motor Electricity consumption | 000000.00K w/H | Display controller according to the Fan motor Frequency converter output real-time Power,total Electricity consumption. |
Fan motor total Electricity consumption | 000000.00K w.H | Display controller according to the Fan motor Frequency converter output real-time Power, total Electricity consumption. |
Fan motor state |
0000 |
Controller obtained by Fan motor Frequency converter reading operation state register value, Display to Fan motor state Display area. |
malfunction |
0000 |
Controller obtained by Fan motor Frequency converter reading malfunction state register value,Displays to malfunction Display area. |
Write frequency | 000.0 | Controller displays the fan motor frequency value obtained out calculate by PID operation here. |
Date | 0000-00-00 | Display date of production. |
Current operating time |
0000:00:00 | Air compressor current operating time. |
Current load | 0000:00:00 | Air compressor current load time. |
Software Version |
CK0000M0000 | |
Check word 1 | 0000 3FFF | |
Check word 2 | 7FFFFFFF_1 |
Input port state |
1 2 3 4 5 6 7 8 9 10 1: Corresponding to the input state of the 5th switching quantity; 2: Corresponding to the input state of the 6th switching quantity; 3: Corresponding to the input state of the 7th switching quantity; 4: Corresponding to the input state of the 8th switching quantity; 5: Corresponding to the input state of the 9th switching quantity; 6: Corresponding to the input state of the 10th switching quantity; When the terminal is closed, the circle color in the input port state is red, and when the terminal is broken, the circle color in the input port state is light red. |
||||
Output port state |
1 2 3 4 5 6 7 8 9 10 1: Corresponding to terminal 17 relay output ; 2: Corresponding to terminal 16 relay output ; 3: Corresponding to terminal 15 relay output ; 4: Corresponding to terminal 14 relay output ; 5: Corresponding to terminal 13relay output ; 6: Corresponding to terminal 12relay output ; When the terminal is closed, the circle color in the output port state is red, and when the terminal is broken, the circle color in the output port state is light red. |
||||
Power-frequenc y motor ¢UI | 000000.0Kw | Display controller sample by the motor real-time electricity and real-time voltage product. | |||
Power-frequenc y motor Electricity consumption |
0000000.0Kw.H |
When the model is power frequency, the power consumption of the motor calculated by the controller is displayed. (for information only) |
|||
Power-frequenc y motor total Electricity consumption |
0000000.0Kw.H |
Display the po
compressor calculated by the controller, and the accumulative electricity consumption. (for information only) |
|||
Power-frequenc y Fan motor ¢UI | 000000.0Kw |
When the power frequency of the fan motor is running, the power consumption of the fan motor calculated by the controller is displayed. (for information only) |
|||
Power-frequenc y Fan motor Electricity consumption | 000000.00Kw.H |
When the power frequency of the fan motor is running, the power consumption of the fan motor calculated by the controller is displayed. (for information only) |
Power-frequenc y Fan motor tota Electricity consumption |
000000.00Kw.H |
Display the power frequency of the air compressor fan motor calculated by the controller and the accumulative power consumption.(for information only) |
Start/stop mode: |
Local/Remot e |
Local mode: remote boot terminal is not functional. Remote mode: remote start terminal function is effective. Note : when a hardware input terminal is set to "remote boot enable", the starting and stopping mode is determined by the state of the hardware. The terminal is remote when closed and local when disconnected. This setting does not work. |
Operation mode: |
Power-frequ ency/soft Starting/ma in Fan motor Variable Frequency/F an motor Variable Frequency/M otor Variable Frequency |
According to the demand, the user chooses the type of air compressor. According to the selected model, refer to the corresponding electrical wiring. |
Communication address: | 0001 | The communication mode is the communication address of the controller when the computer or linkage is used. |
Adjust the back brightness | 0004 | Adjust the back brightness, the higher the value, the stronger the brightness. Adjustable brightness of 1 / 7). |
Communication mode: |
Prohibition / linkage / computer |
When it is set to be prohibited, communication does not work ; Set to communication, as slave, according to the MODBUS RTU protocol to communicate with the external equipment, baud rate: 9600; data format : 8N1; check bit : even check. When set for linkage, multiple air compressors can be operated in a network. |
Pressure: |
Mpa/PSI/BAR |
When set to Mpa, the pressure-related parameter units are displayed as Mpa. When set to PSI, the pressure-related parameter units are displayed as PSI. (Standby) When set to BAR, the pressure-related parameter units are displayed as BAR. (Standby) |
Temperature: |
ºC/ºF |
If set to ºC, the unit of parameters related to temperature is shown as ºC. If set to Fahrenheit, the unit of parameters related to temperature is shown as Fahrenheit. (standby) |
Language | English | English view. |
User password: |
**** | Modifiable user password ; can be reset with old user password or factory password. |